Skip to main content

Pumping station Aqualift S

Duo, GTF 1200-S3, 800-1200 mm, B

PDF product data sheet

The pumping station for faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank is an LW 1000 chamber system made of permanently resistant polymer (PE) with open pump tank and universal connection options. Quick-release closures enable the integrated components to be removed easily. The station is optionally controlled by a user-friendly control unit, which can be integrated in the building management system via a potential-free contact. Alternatively, alarm and collective fault messages can be output via a GSM interface.

  • Maximum safety
  • Flexible installation
  • LW 600 chamber system suitable for underground installation
Item no. 826811B
GTIN 4026092045336
Discount group 3

Pumping station Aqualift S Duo, GTF 1200-S3, 800-1200 mm, B
The pumping station for faecal-free wastewater is equipped with a submersible pump and a backflow preventer. The collection tank is an LW 1000 chamber system made of permanently resistant polymer (PE) with open pump tank and universal connection options. Quick-release closures enable the integrated components to be removed easily. The station is optionally controlled by a user-friendly control unit, which can be integrated in the building management system via a potential-free contact. Alternatively, alarm and collective fault messages can be output via a GSM interface. Version: Type of system: Twin pump station Installation: Wet installation Pump control: Control unit Backflow preventer: integrated Delivery state: Modular set for assembly on site Installation situation: underground installation Type of wastewater: wastewater without sewage General characteristics: Colour: grey Standard: EN 12050-2 Dimensions: Length: 806 mm Width: 806 mm Tank: Number of inlets: 1 ST Inlet nominal size (DN): 100 mm Inlet nominal size (OD): 110 mm Distance pipe bottom inlet to tank bottom: 400 mm Distance from centre of outlet pipe to tank bottom: 482 mm Distance from centre of inlet pipe to tank bottom: 455 mm Connection conduit pipe (DN): 100 mm Pressure pipe connection: horizontal Pressure pipe connection (DN): 32 mm Pressure pipe connection (OD): 40 mm Installation depth: 800 - 1,250 mm Venting connection (DN): 100 mm Groundwater resistant from lower edge of base section: 2,000 mm Clear width of tank (LW): 600 mm Clear width of entry (LW): 600 mm Chamber system: LW 600 Vertical adjustment: vertically adjustable upper section Coverage features: Type of cover: Round cover plate Cover material: Grey iron Colour of cover: black Load class: B 125 (EN 124) Length: 648 mm Width: 648 mm Height: 103 mm Locking: unlocked Pumping device: Pump: GTF 1200 Number of pumps: 2 Max. pumping capacity: 15.5 m3/h Max. pumping height: 9 m Operating mode: S3 - 50 % Power P1: 1.4 kW Power P2: 0.84 kW Speed: 2,650 U/min Max. temperature (permanent) of conveyed material: 40 °C Connection type: coded plug Weight: 10 kg Impeller type: Multi-vane impeller Length of mains cable for pump: 10 m Rated current: 6.2 A Protection class (pump): IP 68 (3m) Protection class: I Type of pump connection cable: H07RN-F 3G 1.0 mm2 Temperature monitoring: integrated Cos phi - power factor: 0.98 Expected service life (number of switching cycles): 150,000 Expected service life (hours of operation): 5,000 Std Insulation class: F Max. permissible switching frequency: 20 1/h Control: Control unit: Comfort Operating voltage: 230 V Mains frequency: 50 Hz Self-diagnosis system (SDS): yes Battery buffering: yes Multi-line display: yes Log book function: yes USB interface: yes GSM interface: yes Potential-free contact: optional Type of fuse required (electrical protection): C 16 A Protection class control unit: IP 54 Length of mains cable for control unit: 1.4 m Type of level measurement: pneumatic Level measurement instrument: Submersible pressure switch Alarm sensor: optical probe

Video

  Title Item no.  
  Title Item no.  
  Title Item no.  
Basic warning device with electronic probe 20222
Basic warning device with optical probe 20223
Compressor set for air bubbling 28048
TeleControl GSM modem for Comfort control units 230V/400V 28792
Connection box for level sensor extension 28799
Replacement set optical probe 80888
10 m probe cable extension set 80889
Cable prolongation set for pump 10 m 80891
Installation set Thermostat, Hygrostat 97713
Outdoor control cabinet W: 590 mm, for control unit installation 97714
Warning beacon for outdoor control cabinet 97715
Outdoor control cabinet W: 460 mm, for control unit installation 97716
Outdoor control cabinet W: 785 mm, for control unit installation 97723
Outdoor control cabinet W: 1115 mm, for control unit installation 97724
  Title Item no.  
Splash guard set for optical probe 28706
Control unit Aqualift Comfort 230 V Duo 28746
Plug 680018
Battery 9 Volt Block 680034
Joint 680067
PE Pressure hose 680071
Diving bell without hose 680108
Clamping Ring for upper section 680276
Pump stand for pumping station Aqualift S 680362
Spiral housing for Ø 30 mm passage 680363
Impeller Ø 30mm passage 680366
Glued connection Height T1 680449
Flap holder 680457
Pump connection 680476
Threaded connection PS Aqualift S duo 680480
Gasket Set LW600/LW1000 duo 680491
Replacement part GTF1200 without floater 680595
Black locking lever for flap holder 680698
Sensor clamp for level sensor & subm. press. switch 680729
Adapter set optical probe 80892
Optical probe with 3 adap. 15 m 80988
Seal for channel passage 110 mm 850117
Seal for upper section 860116
Cover plate,cast iron class B not bolted 860131
  • TÜV test mark (ATTR-376): ID 1111241937
  • Country of origin (ATTR-322): DE
  • Area of application (ATTR-264): drainage
  • Pump type (ATTR-265): submersible pump
  • Pump shaft position (ATTR-266): vertical
  • Pump design (ATTR-267): Dry rotor pump
  • Pump hydraulics (ATTR-268): single stage
  • Pump suction characteristic (ATTR-269): non-self-priming
  • Pump drive (ATTR-270): E-motor for alternating current
  • E-motor, type of startup (ATTR-271): direct
  • Pump casing material (ATTR-272): Polymer
  • Upper tolerance of the operating voltage (+) (ATTR-273): 10  PROZ
  • Lower tolerance of the operating voltage (-) (ATTR-274): 10  PROZ
  • Upper tolerance of the nominal frequency (+) (ATTR-275): 3  PROZ
  • Lower tolerance of the nominal frequency (-) (ATTR-276): 2  PROZ
  • Pump electrical connection (ATTR-277): 1/N/PE 230V
  • Motor pump shaft (ATTR-279): continuous
  • Shaft seal (ATTR-280): RSSR
  • Number of operating pumps (ATTR-281): 1
  • Minimum pumped media temperature (ATTR-282): 0  CEL
  • Maximum operating pressure (Pmax) (ATTR-283): 900  HPA
  • Minimum speed for speed adjustment (ATTR-284): no speed adjustment
  • Start-up current (ATTR-285): 14.9  AMP
  • Vertical installation (ATTR-286): yes
  • Operating mode, twin systems (ATTR-287): redundant
  • Pump (ATTR-4): GTF 1200
  • Number of pumps (ATTR-181): 2
  • Impeller type (ATTR-8): Multi-vane impeller
  • Type of pump connection cable (ATTR-N2): H07RN-F 3G 1.0 mm2
  • Max. permissible switching frequency (ATTR-162): 20  1PH
  • Operating mode (ATTR-10): S3 - 50 %
  • Power P1 (ATTR-F4): 1.4  KWT
  • Power P2 (ATTR-F5): 0.8  KWT
  • Speed (ATTR-F2): 2,650  UMIN
  • Rated current (ATTR-N5): 6.2  AMP
  • Max. pumping capacity (ATTR-F7): 15.5  MQH
  • Max. pumping height (ATTR-F8): 9  MTR
  • Max. temperature (permanent) of conveyed material (ATTR-132): 40  CEL
  • Protection class (ATTR-133): I
  • Connection type (ATTR-N1): coded plug
  • Protection class (pump) (ATTR-125): IP 68 (3m)
  • Length of mains cable for pump (ATTR-11): 10  MTR
  • Temperature monitoring (ATTR-135): integrated
  • Weight (ATTR-191): 10  KGM
  • Cos phi - power factor (ATTR-192): 1.0
  • Insulation class (ATTR-193): F
  • Expected service life (hours of operation) (ATTR-194): 5,000  HUR
  • Expected service life (number of switching cycles) (ATTR-195): 150,000
  • Net weight (ATTR-A3A): 130  KGM
  • Gross weight (ATTR-A3B): 142  KGM
  • Installation depth (ATTR-B2_VB): 800  MMT
  • Length (ATTR-A6A): 806  MMT
  • Width (ATTR-A6B): 806  MMT
  • Volume (ATTR-320): 1.2  MTQ
  • Packaging dimension: length (ATTR-325): 1,200  MMT
  • Packaging dimension: width (ATTR-326): 800  MMT
  • Packaging dimension: height (ATTR-327): 1,220  MMT
  • Dimensions (ATTR-323): 1200X800X1220MM
  • Number of packages (ATTR-321): 0
  • Pressure pipe connection (ATTR-B7): horizontal
  • Chamber system (ATTR-B8): LW 600
  • Type of system (ATTR-2): Twin pump station
  • Installation (ATTR-164): Wet installation
  • Backflow preventer (ATTR-165): integrated
  • Pump control (ATTR-134): Control unit
  • Passage seal for ventilation pipe (DN) (ATTR-183): 100  MMT
  • Passage seal for conduit pipe (DN) (ATTR-184): 100  MMT
  • Control unit (ATTR-S2): Comfort
  • Self-diagnosis system (SDS) (ATTR-S5): yes
  • Battery buffering (ATTR-S6): yes
  • Multi-line display (ATTR-S7): yes
  • Log book function (ATTR-S8): yes
  • USB interface (ATTR-S9): yes
  • GSM interface (ATTR-S10): yes
  • Potential-free contact (ATTR-S11): optional
  • Length of mains cable for control unit (ATTR-S12): 1.4  MTR
  • Operating voltage (ATTR-S13): 230  VLT
  • Mains frequency (ATTR-S14): 50  HTZ
  • Protection class control unit (ATTR-S4): IP 54
  • Alarm sensor (ATTR-S1): optical probe
  • Type of level measurement (ATTR-7A): pneumatic
  • Level measurement instrument (ATTR-7B): Submersible pressure switch
  • Type of fuse required (electrical protection) (ATTR-S17): C 16 A
  • Type of cover (ATTR-A21): Round cover plate
  • Colour of cover (ATTR-A2A): black
  • Load class (ATTR-A2B): B 125 (EN 124)
  • Locking (ATTR-A2D): unlocked
  • Cover material (ATTR-A2E): Grey iron
  • Length (ATTR-A2M): 648  MMT
  • Width (ATTR-A2N): 648  MMT
  • Height (ATTR-A2P): 103  MMT
  • Clear width of entry (LW) (ATTR-B13): 600  MMT
  • Clear width of tank (LW) (ATTR-B14): 600  MMT
  • Number of inlets (ATTR-B1B): 1  PCE
  • Inlet nominal size (DN) (ATTR-B1CA): 100  MMT
  • Inlet nominal size (OD) (ATTR-B1CB): 110  MMT
  • Distance from centre of inlet pipe to tank bottom (ATTR-B6): 455  MMT
  • Distance pipe bottom inlet to tank bottom (ATTR-B1D): 400  MMT
  • Distance from centre of outlet pipe to tank bottom (ATTR-B15E): 482  MMT
  • Connection conduit pipe (DN) (ATTR-B3): 100  MMT
  • Venting connection (DN) (ATTR-B4): 100  MMT
  • Pressure pipe connection (DN) (ATTR-B17): 32  MMT
  • Pressure pipe connection (OD) (ATTR-B18): 40  MMT
  • Groundwater resistant from lower edge of base section (ATTR-B12): 2,000  MMT
  • Vertical adjustment (ATTR-177): vertically adjustable upper section
  • Declaration of Performance (DOP) (ATTR-292): 009-072
  • Installation situation (ATTR-1): underground installation
  • Wastewater quantity (ATTR-310): Medium
  • Type of wastewater (ATTR-6): wastewater without sewage
  • Colour (ATTR-102): grey
  • Standard (ATTR-9): EN 12050-2
  • CE marking (ATTR-A5B): yes
  • Delivery state (ATTR-189): Modular set for assembly on site
  • Brand (M-ATTR-001): KESSEL
  • Product group (M-ATTR-002): Lifting stations
  • Product type (M-ATTR-003): Pumping station
  • Product family (M-ATTR-004): Aqualift
  • Product name (M-ATTR-005): Aqualift S